Han- yellock – Northern Connectors Harting Han-Yellock Industrial Connectors User Manual

Page 5

Advertising
background image

25.

05

Han-

Yellock

Han-Yellock

®

Han-Yellock

®

adapter frame

Han-Modular

®

series interfaces can be established

using the Han-Yellock

®

adapter frame. The connection

is based on a male/female contact arrangement.

Inserting the adapter frame in the housing:

• The adapter frame can be snapped into the hou-

sing, bulkhead mounting, on the termination side

and the mating side (refer to the illustration).

• The lateral plastic tabs („B“) are pressed into the

metal clamps on the housing.

• The adapter frame then snaps in with a distinctly

audible click.

① metal clamp

Removal the adapter frame:

• The removal tool part no.

"https://b2b.harting.com/ebusiness/en/

11 99 000 0001

"

is re-

quired for disassembly.

• The removal tool is inserted into the metal clamp

and pressed down as shown in the following

illustration. A screwdriver need also be placed

into the notch in the housing.

• The removal tool should then be pulled outwards

to remove the adapter frame from the housing.

• The removal can be made from the termination

side as well as from the mating side.

• The process is identical for both housings, bulk-

head mounting, and carrier hoods.