SECTION 8. MAINTENANCE AND SERVICING
169593
176
Revision B
8.12.8.5 AGCO
a. Maintain a .02 in. (0.5 mm) gap between sensor
disc (A) and sensor (B). Adjust by bending
support (C).
b. Replace sensor as follows:
1. Disconnect
connector
(D).
2. Cut plastic tie (E) securing harness to
cover.
3. Remove screws (F), and remove sensor (B)
and harness. Bend cover (G) (if necessary)
to remove harness.
4. Feed wire of new sensor behind cover (G)
through chain case.
5. Locate new sensor in support (C), and
attach with two screws (F).
6. Adjust gap between sensor disc (A) and
sensor (B) to .02 in. (0.5 mm).
7. Connect to harness at (D).
C
E
G
F
A
B
C
SINGLE REEL
DUAL REEL
D
D
Advertising