Restarting the as400 – Retsch AS 400 User Manual

Page 15

Advertising
background image

06.11.2012

Retsch GmbH

15

Operating the AS400 control
Switching on and off

E

The main switch E is located at the left-front under the AS400
control
.

Turn the main switch on

On illuminates in the memory display

050 illuminates in the speed/“g“ display

The interval off LED illuminates

Two bars illuminate in the time display

The AS400 control is now ready for operation, without intermit-
tent mode, in continuous duty, at a speed of 50 r.p.m..

Automatic recognition of imbalance

4

5

15

16

The AS400 is equipped with a function which automatically recognises any
imbalance.
Even running of the AS400 is monitored by imbalance sensors. In case of an
acceleration >=0.3g, the sensors switch off the drive unit of the AS400.

Imbalance triggering characteristic

Display 5 flashes

The green LED above button 15 extinguishes

The red LED above button 16 lights up

The AS400 can no longer be started.

Resetrestarting the AS400

Display 5 flashes

Press button 4 to reduce the speed until display 5 no longer flashes

The AS400 can now be started again by pressing button 15 once more.

Necessary reductions :

201 – 300 reduce to 200

151 – 200 reduce to 150

101 – 150 reduce to 100

76 – 100 reduce to 75

51 – 75 reduce by 1 rpm

Speeds of <050 are not possible