Description, Housing, 2 • sample draw combustible gas detector – RKI Instruments 35-3000RKA-LEL User Manual

Page 2

Advertising
background image

2 • Sample Draw Combustible Gas Detector

Description

This section describes the components of the sample draw combustible gas detector. The
sample draw detector consists of the housing, flow system, and detection system.

Figure 1: Sample draw Combustible Gas Detector Component Location

Housing

The sample draw detector’s fiberglass housing is weather- and corrosion-resistant. It is
suitable for installation where general purpose equipment is in use.

The housing door is hinged on the left side and is secured by two latches on the right side.
The flowmeter and status lights are visible through a window in the housing door.

Four mounting feet are attached to the back of the housing (one at each corner). Use the
mounting feet to install the housing to a vertical surface. Use the two conduit hubs on the
bottom of the housing to make wiring connections.

An aluminum subpanel is mounted to the interior of the housing. The sample draw
detector’s internal components are mounted to the subpanel.

Flow Alarm Se tpo int
Adjustment Po ten tiomet er

Externa l Wiring
Terminal Strip

In le t

Se nso r Wiring
Terminal St rip

Exh aust

Terminal Block

3/4" C on du it
Hub, 2X

Flowmeter

Particle filter

Byp ass valve

LE L Transmitter

Pu mp /flo w sw itch
termina l block

Flow Adjust
Potentiometer

Fail LE D

Pilot LE D

TP

+

TP

ZERO

SPAN

GND

24V

4-20

RED

WHT

GRN

BLK

POWER/SIG

SENSOR

P/N 57-1050RK

REV. 0

Factory Se t Pots

LEL
sensor

Zero Pot

Span Pot

JUMPER PI NS FOR
FACTORY U SE ONLY

Test Po ints
10 0 - 500 mV range

Mounting
Foot, 4X

Advertising