RKI Instruments 65-2340RKSS User Manual

Page 21

Advertising
background image

65-2340RKSS Toxic Gas Transmitter • 17

71-0302RK

65-2340RKSS Operator’s Manual (this document)

81-0076RK

Zero air calibration cylinder, 17 liter steel

81-0076RK-01

Zero air calibration cylinder, 34 liter steel

81-0076RK-03

Zero air calibration cylinder, 103 liter steel

81-0170RK-02

Calibration cylinder, 5 ppm SO

2

in nitrogen, 58 liter aluminum

81-0170RK-04

Calibration cylinder, 5 ppm SO

2

in nitrogen, 34 liter aluminum

81-0175RK-02

Calibration cylinder, 10 ppm NH

3

in nitrogen, 58 liter aluminum

81-0175RK-04

Calibration cylinder, 10 ppm NH

3

in nitrogen, 34 liter aluminum

81-0185RK-02

Calibration cylinder, 0.5 ppm PH3 in nitrogen, 58 liter aluminum, used to calibrate
PH

3

and AsH

3

detectors, see conversion factor on AsH

3

plug-in sensors

81-0185RK-04

Calibration cylinder, 0.5 ppm PH3 in nitrogen, 34 liter aluminum, used to calibrate
PH

3

and AsH

3

detectors, see conversion factor on AsH

3

plug-in sensors

81-0190RK-02

Calibration cylinder, 5 ppm Cl

2

in nitrogen, 58 liter

81-0190RK-04

Calibration cylinder, 5 ppm Cl

2

in nitrogen, 34 liter

81-0192RK-02

Calibration cylinder, 2 ppm Cl

2

in nitrogen, 58 liter, aluminum

81-0192RK-04

Calibration cylinder, 2 ppm Cl

2

in nitrogen, 34 liter aluminum

81-0196RK-02

Calibration cylinder, 10 ppm HCN in nitrogen, 58 liter aluminum

81-0196RK-04

Calibration cylinder, 10 ppm HCN in nitrogen, 34 liter aluminum

81-1050RK

Regulator with gauge and knob, 0.5 LPM, for 17 liter and 34 liter steel calibration
cylinders (used for 34 liter zero air cylinder only)

81-1051RK

Regulator with gauge and knob, 0.5 LPM, for 34AL/58/103 liter calibration
cylinders

81-1051RK-25

Regulator with gauge and knob, 0.25 LPM, for 34AL/58/103 liter calibration
cylinders (used to calibrate NH

3

toxic detector only)

81-1138RK

Calibration cup, general (SO

2

), for ESM-01, use 0.5 LPM flow

81-1138RK-CL2

Calibration cup, for ESM-01 Cl2, use 0.5 LPM flow

81-1138RK-NH3

Calibration cup, for ESM-01 NH3, use 0.25 LPM flow

81-F503RK

Calibration kit, includes regulator, calibration cup, and a 58 liter 10 ppm NH

3

in

nitrogen aluminum calibration cylinder

81-F503RK-LV

Calibration kit, includes regulator, calibration cup, and a 34 liter 10 ppm NH

3

in

nitrogen aluminum calibration cylinder

81-F603RK

Calibration kit, includes regulator, calibration cup, and 58 liter 2 ppm CL

2

in

nitrogen aluminum calibration cylinder

Table 4: Parts List

Part Number

Description

Advertising