Figure 3: wiring the detector to the amplifier – RKI Instruments 65-2405RK-04 User Manual

Page 11

Advertising
background image

65-2405RK-04 Combustible Gas Transmitter • 7

Figure 3: Wiring the Detector to the Amplifier

10. Reinstall the detector terminal strip into its socket.

11. If shielded cable is used, connect the cable’s drain wire to an available chassis (earth)

ground at the amplifier junction box. The amplifier mounting screw is a convenient
grounding location. Install a lug on the shield drain wire or wrap the shield drain wire
around the mounting screw. Do not connect the shield drain wire at the detector
junction box.

G

RB

PW

R

/

S

I

G

W

LE

L

S

Amplif ier

Black
Green

Whit e
Red

IR L EL Detector

Cab le

Shield

Det ector

Term inal

Strip

Bla ck
Green
Wh it e

Red

Amp lif ie r
J-Box

Det ector J-Box

Calibration Cup/Splash G uard

Advertising