Description

This section describes the components of the combustible gas transmitter. The transmitter
is a 4 - 20 mA type detector head. It consists of the combustible gas detector, calibration
cup/splash guard, amplifier, the amplifier junction box, and the detector junction box.
The two junction box configuration is intended for situations where the detector needs to
be installed at an inaccessible location. The detector junction box can be installed at the
inaccessible location and the amplifier junction box can be installed in a more readily
accessible area.

Figure 1: Combustible Gas Transmitter Component Location

Controller T erm inal
Strip

Am plifier

LE

L

PW

R

/

S

IG

G

S

2

0

0

1

S

5

7

-105

3R

K

B

R

W

Com bustible Gas D etector

Am plifier J-Box

Detector J-B ox

Term inal S trip

Jum per P ins ,

Factory U se

Only

Factory A djust

Pot

Factory A djust P ot

Span P ot

Zero P ot

SPA

N

ZE

R

O

Se

n

s

o

r

Cu

r

re

n

t

m

A

+ Test P oint

- T est Point

Detector Ter minal

Strip

Calibration C up/S plash Guard

Advertising