Parts list – RKI Instruments GD-70D4H-XX User Manual

Page 12

Advertising
background image

9 • Model GD-70D4H-XX Sample Draw Transmitter

5.

Turn the cover over and locate the Audio Select switch at the top of the cover as
shown in the figure below.

Figure 7: Horn/Strobe Cover

6.

The Audio Select switch can be set at any number between 1 and 6. Numbers 1-3 all
produce an intermittent buzzing sound with 1 being the loudest and 3 being the
quietest. Numbers 4-6 all produce a steady buzzing sound with 4 being the loudest
and 6 being the quietest. The factory setting is 2.

7.

Turn the Audio Select switch so that the selection arrow is pointing to the desired
number.

8.

Place the cover over the base and push in and down in order to reinstall the cover.
Make sure that the cover is sealed to the base by the gasket.

9.

Screw the captive screw at the bottom front of the horn/strobe back in.

10. Turn on power (100 - 240 VAC) to the GX-70D4H-XX.

11. Turn on the GD-70D. See the GD-70D Operator’s Manual for instructions.

Parts List

Table 4 lists replacement parts and accessories for the GD-70D4H-XX.

Table 2: Parts List

Part Number

Description

06-1273RK

1/4” O.D. x 1/8” I.D. Teflon PTFE tubing

17-4820RK

Sample fitting, 1/4” tube bulkhead union

18-0107RK

3/4” conduit hub

49-0108RK

Power Supply, 24 VDC

51-0096RK

Horn/strobe, 10 - 33 VDC, NEMA 4X

80-0226RK

Hydrophobic filter with push fittings for 1/4 inch O.D. tubing

Audio Select Switch

AUDIO
SELECT

6

Strobe Brightness Switch
(DO NOT ADJUST)

1

2

3

4 5

CANDELLA S ELECT