1 • Model GD-70D4H-XX Sample Draw Transmitter

Overview

This supplement describes the differences and additional features of the Model GD-
70D4H-XX compared to the GD-70D. It also describes how to install, startup, maintain,
and calibrate the GD-70D4H-XX. See the GD-70D Operator’s Manual for information
specific to the GD-70D.

Specifications

Table 1 lists specifications for the GD-70D4H-XX.

WARNING: When using the GD-70D4H-XX, you must follow the instructions and

warnings in this manual to assure proper and safe operation of the
GD-70D4H-XX and to minimize the risk of personal injury. Be sure to
maintain and periodically calibrate the GD-70D4H-XX as described in this
manual.

Table 1: Specifications

Target Gas & Detector Range

Refer to the RKI Instruments Inc. List of Detectable Gasses

Enclosure Type

NEMA 4X

Sampling Method

Sample-draw

Input Power

115/220 VAC

Signal Output

4 to 20 mA

Response Time

90% in 60 seconds

Accuracy

See GD-70D manual

Flow Rate

Approximately 0.5 liters/minute

Recommended Sample Tubing

1/4” O.D. x 1/8” I.D. Teflon PTFE