Do not inst all a t al ti tude above 6,800 feet, 26 19. high altitude installation – Schwank supraSchwank User Manual

Page 26

Advertising
background image

supra/primo Manual

IM091112

RD: APR 2013

RL: 13B

26


19. HIGH ALTITUDE INSTALLATION

This heater not to be installed at altitude above:

NG = 6,800 feet; LPG = 4,500 feet

USA:

The factory installed orifice for this appliance is approved for altitudes zero to 2000

feet above sea level. When installed above 2000 feet, refer to information below.
Canada

: The factory installed orifice for this appliance is approved for altitudes zero to

4500 feet above sea level. When installed above 4500 feet, refer to information below.

When this appliance is installed above the standard altitude stipulated for the USA or Canada,
the input must be de-rated by 4% for each 1000 ft above sea level. The orifice must be
changed according to the chart below - ensure you search the correct model. Check with your
local utility regarding the gas supply and the de-rating of this appliance.

MODEL

FOR USE AT ALTITUDES ABOVE (FEET)

Gas Orifice Drill Size / Part#

Supplied

USA Only

USA & CANADA*

0

2000

3000

4000

5000

6000

DO NOT INST

ALL
A

T AL

TI

TUDE ABOVE

6,800

FEET

primoSchwank 10

NG

2.65 mm

JO-0310-NG

2.60 mm

JO-1260-MM

2.57 mm

JO-1257-MM

2.53 mm

JO-1253-MM

2.49 mm

JO-1249-MM

2.45 mm

JO-1245-MM

primoSchwank 10

LPG

1.67 mm

JO-0310-LP

1.64 mm

JO-1164-MM

1.62 mm

JO-1162-MM

1.60 mm

JO-1160-MM

DO NOT INSTALL

primoSchwank 15

NG

3.20 mm

JO-0313-NG

3.14 mm

JO-1314-MM

3.10 mm

JO-1310-MM

3.06 mm

JO-1306-MM

3.01 mm

JO-1301-MM

2.96 mm

JO-1296-MM

primoSchwank 15

LPG

2.10 mm

JO-0313-LP

2.06 mm

JO-1206-MM

2.04 mm

JO-1204-MM

2.01 mm

JO-1201-MM

DO NOT INSTALL

primoSchwank 20

NG

3.75 mm

JO-0311-NG

3.68 mm

JO-1368-MM

3.64 mm

JO-1364-MM

3.59 mm

JO-1359-MM

3.53 mm

JO-1353-MM

3.48 mm

JO-1348-MM

primoSchwank 20

LPG

2.43 mm

JO-0311-LP

2.39 mm

JO-1239-MM

2.36 mm

JO-1236-MM

2.32 mm

JO-1232-MM

DO NOT INSTALL

primoSchwank 30

NG

4.55 mm

JO-0312-NG

4.47 mm

JO-1447-MM

4.41 mm

JO-1441-MM

4.35 mm

JO-1435-MM

4.29 mm

JO-1429-MM

4.22 mm

JO-1422-MM

primoSchwank 30

LPG

2.90 mm

JO-0312-LP

2.84 mm

JO-1284-MM

2.81 mm

JO-1281-MM

2.77 mm

JO-1277-MM

DO NOT INSTALL

supraSchwank 10

NG

2.35 mm

JU-0319-NG

2.31 mm

JU-1231-MM

2.28 mm

JU-1228-MM

2.25 mm

JU-1225-MM

2.21 mm

JU-1221-MM

2.18 mm

JU-1218-MM

supraSchwank 10

LPG

1.50 mm

JU-0319-LP

1.47 mm

JU-1147-MM

1.45 mm

JU-1145-MM

1.43 mm

JU-1143-MM

DO NOT INSTALL

supraSchwank 15

NG

2.85 mm

JU-0318-NG

2.80 mm

JU-1280-MM

2.76 mm

JU-1276-MM

2.73 mm

JU-1273-MM

2.68 mm

JU-1268-MM

2.64 mm

JU-1264-MM

supraSchwank 15

LPG

1.85 mm

JU-0318-LP

1.82 mm

JU-1182-MM

1.79 mm

JU-1179-MM

1.77 mm

JU-1177-MM

DO NOT INSTALL

supraSchwank 20

NG

3.35 mm

JU-0320-NG

3.29 mm

JU-1329-MM

3.25 mm

JU-1325-MM

3.20 mm

JU-1320-MM

3.16 mm

JU-1316-MM

3.10 mm

JU-1310-MM

supraSchwank 20

LPG

2.18 mm

JU-0320-LP

2.14 mm

JU-1214-MM

2.11 mm

JU-1211-MM

2.08 mm

JU-1208-MM

DO NOT INSTALL

supraSchwank 30

NG

4.05 mm

JU-0319-NG

3.98 mm

JU-1398-MM

3.93 mm

JU-1393-MM

3.87 mm

JU-1387-MM

3.81 mm

JU-1381-MM

3.75 mm

JU-1375-MM

supraSchwank 30

LPG

2.60 mm

JU-0319-LP

2.55 mm

JU-1255-MM

2.52 mm

JU-1252-MM

2.49 mm

JU-1249-MM

DO NOT INSTALL

Advertising