Preventative care and maintenance, Storage 13. safety – Schwank Parasol Series Portable User Manual

Page 14

Advertising
background image

4002/5-CB I&O Manual

IM080811

RD: NOV 2013

R.L. 02B

BA



Check periodically for leaks in the system, or immediately when you smell gas.



In case a leak is detected, extinguish all open flames in the area.



Never leak test while smoking.



If you are unable to repair a leak, turn off gas supply at the cylinder valve and con-
tact your gas supplier or a qualified, licensed gas technician.



Do not alter or modify this heater in any way


When heater is not in use for a prolonged period of time, remove gas cylinder.

Verify that the gas valve is fully and tightly closed.

Do not store the gas cylinder indoors.

Store gas cylinder in a well ventilated area.

For more compact storage and to avoid damage, the reflector may be removed

12. PREVENTATIVE CARE AND MAINTENANCE


The burner area is likely to attract spiders, especially inside orifices. Once a year, the heater should be
inspected for spider webs, insects, and debris around burners and orifices. Plugged injectors or orifices
will obstruct the gas flow to the burner. This will result in burner malfunction or possible damage.

When heater is warming up or cooling down a pinging metallic noise is normal.

Have heater inspected if.…..



you smell gas combined with yellow tipped flames on burner.



heater does not provide expected heat capacity



burner makes little popping sounds while operating (other than when shutting down

after being turned off).

Page 11

11. STORAGE

13. SAFETY

Advertising