2. INSTALLATION REQUIREMENTS

This Portable Patio Heater must always maintain proper clearance to combustible materials.
(Top 18” sides 24” below 24”).

The heater must always be placed on a stable, solid level surface.

Do not use this heater in an explosive atmosphere. Keep heater away from areas where

gasoline or other flammable liquids or vapors are stored.

WARNING: Improper operation, installation, adjustment, alteration, servicing or
maintenance can cause fire, severe property damage, serious injury or death.
Carefully read this User Guide before assembling and setting up the heater.

3. GAS SUPPLY: PROPANE

(CYLINDER NOT INCLUDED)

A dented, rusted or damaged propane cylinder may be hazardous and should be checked
by your gas supplier. The heater comes equipped with a hose assembly for hook-up to a
standard propane gas tank. For your safety:



Never use a propane cylinder with a damaged valve connection.



Never connect an unregulated propane cylinder to the heater

This appliance is a transportable infrared patio, deck and garden heater for operation with LPG
(Liquefied Petroleum Gas).

The 4005-CB & 4002-CB burner is controlled and adjusted by the gas control knob located
below the burner, and the gas supply is controlled by the valve on the portable propane gas
cylinder. The gas supply is fed up through the inside of the pole using flexible gas hose.


These installation and operating instructions are intended only for patio heater MODELS 4005-CB & 4002-
CB.

All installations must conform to all local and national code requirements including the current CAN/CGA-
B149.1-05 (latest edition) installation code and the ANSI Z223.1 (latest edition) for the U.S.A. for gas burn-
ing appliances and equipment.

The propane cylinder must be designed to provide for vapor withdrawal from the
operating cylinder. Although gas connections on the heater are leak tested at the factory
prior to shipment, potential hazards could result during shipment.

For your safety a complete gas tightness check of all connections and hoses, must also
be performed at the installation site prior to use, due to potential shipment hazards.

1. GENERAL

Page 1

REFER TO INFORMATION REGARDING LEAK TESTING ON THE NEXT PAGE