GP-MSER-BX-11A

SER / IR Manual

RD: March 2006

RL: 11A

KH

17. WIRING DIAGRAM FOR SER / IR-45:
(See SER / IR 60 - Section 19)

Page 16

THERMOSTAT OPTIONS:

INSTALL 120V THERMOSTAT IN SERIES WITH 3
PRONGED PLUG RECEPTACLE .

REMOVE 3 WIRE CORD FROM HEATER AND
INSTALL IN SERIES WITH 120V SUPPLY TO
HEATER TERMINAL BLOCK.

LEAVE JUMPER
IN UNLESS 24V
RELAY IS
BEING
INSTALLED