Schwank SER(IR) User Manual

Page 5

Advertising
background image

GP-MSER-BX-11A

SER / IR Manual

RD: March 2006

RL: 11A

KH

Page 1

SER / IR SERIES

GAS INFRA-RED TUBE HEATER

INSTALLATION INSTRUCTIONS

1. GENERAL

The following tube lengths and corresponding BTU input ratings are available:

TABLE 1

* manufactured and shipped in 10-ft. lengths, due to the swaged overlap, total length is slightly shorter
than multiples of 10 feet.

MODEL

OVERALL HEATER

LENGTH* (FT)

APPROX NET

WEIGHT IN LBS

SER / IR 60-30

30’ 8”

120

SER / IR 60-20

21’

90

SER / IR 45-20

21’

90

SER / IR 45-10

11’ 4”

60

Btu/hr INPUT

ZERO TO 4,500’

ABOVE SEA LEVEL

60,000

60,000

45,000

45,000

SER / IRU 60-10

60,000

12’ 7”

90

Installation of the SER / IR Series gas-fired tube heaters must be performed by a qualified, li-
censed gas fitter and conform to all Manufacturers heating installation design procedures, in-
cluding ventilation. All local, provincial and national code requirements must be met, ANSI/
NFPA No. 88B 1985 (latest edition), which states clearances to combustible construction or
material in storage, from heater and vent, must conform to standard NFPA No. 54 (ANSI
Z223.1 latest edition), in the U.S.A. In Canada the current CSA -B149.1-00 installation codes
for gas-burning appliances and equipment, as well as the Canadian electrical code CSA C22.1 .
SER / IR Series heaters may be installed for heating of residential indoor spaces. It is beyond
the scope of these instructions to embrace all conditions that will be encountered. All system
piping must be supported in accordance with acceptable industry practices, local codes, and ap-
plicable standards.

Advertising