Page 5 – Schwank SCH-200 Construction User Manual

Page 9

Advertising
background image

SP-MCH2-BX-07A

SCH-200 MANUAL

R.D: Sept 2004

RL: 7

KH

1.6 LIGHTING / SHUTDOWN INSTRUCTIONS

2.0 MAINTENANCE

This heater should be cleaned at least once annually with a dry cloth. This heater should be inspected before
each use and at least once annually by a qualified service person.

The gas hose assembly shall be visually inspected prior to each use of the heater. If damage is evident it must be
replaced prior to the heater being placed into operation. For replacement part information, see page 9 & 10.

LP model heaters should use a standard LP gas cylinder. Cylinder must be located a minimum of 10 feet away
from heater while heater is in operation. The cylinder must be provided with a system for vapor withdrawal. The
gas must be turned off at the LP gas supply cylinder when the heater is not in use.

The connection of the gas cyl-

inder should be made with the #510 connector which tightens by turning the threads to the left. To disconnect the
fitting make sure the gas is turned off, and loosen threads by turning them to the right. When heater is to be
stored indoors the connection between the LP gas cylinder and the heater must be disconnected. The cylinder
must be stored in accordance the Canadian National Code for the Storage and Handling of L.P. Gases.

Keep appliance area free and clear from combustible materials, gasoline and other flammable vapors and liquids.
Ensure that the flow of combustion and ventilation air is free from all obstructions.


1. Set thermostat to “coolest” (lowest) setting.

2. Pre-purge gas line prior to lighting.

3. Open the door in the compartment above filter section.

4. Turn gas control knob clockwise to OFF. Wait five
minutes to dissipate any unburned gas. Sniff around
the appliance near the floor.
Don’t relight pilot if you smell gas.

5. Turn gas control knob counterclockwise to PILOT.
Push down and hold the knob while you light pilot
burner.

6. Hold the gas control knob down about one minute,
then release. If the pilot goes out, turn gas control
knob clockwise to OFF. Repeat steps 1-3.

7. Release gas control knob. If pilot remains lit, turn
counterclockwise to ON.

8. Close the door.

9. Set thermostat to desired setting.

Page 5