Wire diagram, Layout, 12vdc @ .6amp – SDC Z7200 CYLINDRICAL LOCK User Manual
Page 4: 24vdc @ .3amp, Request-to-exit output spdt, 3 amps @ 30vdc, Red(+) wht(-)

P:\INSTALLATION INST\ELECTRIFIED LOCKSET\Z7200\INST-Z7200.vsd REV G 04-13 Page 4
REQUEST-TO-EXIT OUTPUT SPDT, 3 AMPS @ 30VDC
COM = WHT/RED
N/C = ORG/RED
N/O = YEL/RED
REX
WIRE DIAGRAM
Flat (No Bevel)
5/32" (4mm)
1-3/4” Door
1-5/8"
(41mm)
1/8" (3mm)
Holes
2-3/8" (60mm) BACKSET
MARK CENTER OF
2-1/8” (54mm)
HOLE ON DOOR FACE
2-3/4” (70mm) BACKSET
(FOR METAL
DOORS ONLY)
DOOR EDGE
2X 5/16" (8mm)
hole
High Bevel
Low Bevel
1" (25mm)
Hole
2-3/4”
(70mm)
LAYOUT
2-15/32" (62.7mm)
(FOR METAL
DOORS ONLY)
DO NOT USE AS A PHYSICAL TEMPLATE. THIS LAYOUT
IS INTENDED AS A DIMENSIONAL REFERENCE ONLY.
USE THE TEMPLATE PACKAGED WITH THE LOCK
Use of the PR-7200 limits the power consumption and reduces operating temperature.
RED
BLK
WHT
BLU
RED(+)
WHT(-)
12vdc @ .6AMP
LOCKSET PR-7200
POWER REGULATOR
BLU
WHT
TO PWR
SUPPLY
RED (+)
BLK (-)
24vdc @ .3AMP
RED(+)
WHT(-)
RED
BLK
WHT
BLU
LOCKSET PR-7200
POWER REGULATOR
BLU
WHT
TO PWR
SUPPLY
RED (+)
BLK (-)