Step 6 – SDC E300 SERIES MAGNETIC LOCK User Manual
Page 3
![background image](/manuals/572404/3/background.png)
P:\INSTALLATION INST\Electromagnetic Locks\EXCEL\INST-E300.vsd REV -
07-10 Page 3
7. Select jumper position for 12VDC or 24VDC. Connect power to magnetic lock.
STEP 6
A/C
MAINS
POWER
SUPPLY
12VDC
or
24VDC
+
-
SWITCH or ACCESS CONTROL
8. Test operation. When all is operating properly, tighten
all screws as shown. Install anti-tamper plugs over socket
screws using a soft hammer to avoid damage to the housing.
6. Holding the magnet housing at each end, engage the entire length of the interlock detail, by pushing towards the
door. Tap with a soft hammer to ensure proper alignment and engagement.
CAUTION: The lock body must be held in place until secured with mounting screws. Secure socket head
screws provided inside the housing at each end. Start screws into threads carefully to avoid stripping the
threads. Check alignment and tighten screws. Pull wires through frame, mounting plate and magnet housing
COM
NC
NO
Door Position Sensor (Reed switch)
RED (open with door closed)
GREEN (closed with door closed)
BLACK
+
-
N
O
C
N
C
1
2
3
4
5
Power
Supply
Lock Status
Switch
Voltage Jumper
12VDC
24VDC
A RED LED INDICATES
ENERGIZED & UNSECURED
(GREEN=ENERGIZED & SECURE)
LED