Valve and tubing connections – Bradley Smoker TDB3108 User Manual

Page 16

Advertising
background image

TDB3108, WF3208 Terreon

®

54" Circular

Installation

16

4/6/2007

Bradley Corporation • 215-1187 Rev. N; EN 06-915B

5

Valve and tubing connections

TEE
269-764

VOLUME CONTROL
S02-045

THERMOSTATIC
MIXING VALVE
ASSEMBLY
S67-597

STOP/CHECK

VALVE

1/2" DIA. TUBE

FROM SPRAYHEAD

1/2" DIA. TUBE

R68-600012

SOLENOID

ASSY.

S08-055

FLEXIBLE

HOSE

FILTER WASHER

Figure 10a

Figure 10b

NUT

MALE TUBE
CONNECTOR

TUBING

VALVE ASSEMBLY S50-369

NOTE: Flush supply lines before making connections.

Do not apply pipe sealant to compression fittings.

CONNECT 1/2" DIA. TUBING TO TEE AND SOLENOID ASSEMBLY, TWO PLACES. THE MALE CONNECTOR
(FIGURE 10B) FOR THE VALVE ASSEMBLY WILL REMAIN TIGHT AND LEAKPROOF WHEN TUBING IS CUT AND INSTALLED PROPERLY.
FOLLOW THE PROCEDURES BELOW WHEN INSTALLING TUBING TO ENSURE THAT YOU ACHIEVE A LEAKPROOF SEAL.

A

USING A SHARP RAZOR, CUT TUBING SQUARELY AND REMOVE ANY BURRS. DO NOT PINCH OR CRUSH END OF TUBING.

LOOSEN NUT ON FITTING. MOISTEN END OF TUBE AND PUSH INTO FITTING UNTIL IT IS FIRMLY SEATED. TIGHTEN NUT TO SECURE
TUBE TO FITTING (MAKE SURE NUT IS SECURELY TIGHTENED).

IF CONNECTOR LEAKS, RESEAT TUBING ACCORDING TO ABOVE PROCEDURE. IF LEAKING PERSISTS, REPLACE MALE
CONNECTOR, OR CALL YOUR BRADLEY REPRESENTATIVE FOR ASSISTANCE.

HANG VALVE ASSEMBLY ON PEDESTAL BRACKET (SEE FIGURE 11 ON PAGE 17). USE WIRE TIE TO SECURE VALVES.

B

CONNECT THE 1/2" NPT FEMALE END OF THE STOP/CHECK VALVES TO THE ROUGH-INS.

C

ATTACH FLEXIBLE HOSING TO THERMOSTATIC MIXING VALVE, TWO PLACES.

D

INSERT THE FILTER WASHERS (PROVIDED) INTO THE SWIVEL NUT AT THE END OF THE SUPPLY HOSES AND CONNECT TO THE
STOP/CHECK VALVES.

E

NOTE!

For “O” and “B” units (overhead supplies) Skip steps C through E