Electrical connections for Adaptive Infrared

START-UP NOTE: Do not use for two minutes after making power connection. The sensors will take up

to eight minutes (without being used) to adapt to the bowl if another object is detected during the
two-minute start-up period.

I.R. MODULE

S50-344

TOP VIEW MODULE

ASSEMBLY

CONNECT WIRES

AS SHOWN

VALVE ASSY.
S50-369

110/24 VAC
TRANSFORMER
S83-134

F = FEMALE CONNECT
M = MALE CONNECT

WIRE

ADAPTER

269-620

S53-261

(S53-261A) C

RED

(S53-261A) A

RED

(S53-272) B

BLACK

WINDOW

269-1351

Figure 12

CONNECT THE THREE WIRES FROM THE INFRARED MODULE ASSEMBLY TO THE VALVE ASSEMBLY. ATTACH TWO OF THE FEMALE
CONNECT WIRES TO THE SOLENOIDS AS SHOWN IN FIGURE 12. ATTACH THE MALE CONNECT WIRE TO ONE OF THE 24 VAC
TRANSFORMER LEADS. ATTACH THE REMAINING TRANSFORMER LEAD TO THE SOLENOID WIRE ADAPTER (SEE FIGURE 12).

A

CONNECT 24 VAC TRANSFORMER PROVIDED TO POWER SOURCE.

B

TURN SUPPLIES ON. OPEN CHECK/STOP VALVES COMPLETELY.

C

OPEN VOLUME CONTROL VALVE COMPLETELY AND CHECK PIPING INSTALLATION FOR LEAKS.

D

PASS YOUR HAND IN FRONT OF EACH SENSOR UNTIL AIR IS PURGED FROM THE LINES.