Frequently asked questions and operating guide, Problem probable cause what to do – Summit FF1935PL User Manual

Page 33

Advertising
background image

33

frequently asked questions and operating guide

Problem

Probable Cause

What to Do

External

condensation on

exterior door

(depending on

model)

External

Condensation

Refrigerator is

not cooling items

Unusual Noises

Smart Station

isn’t chilling

Ice cubes

vary in size

See installation instructions.

See operating and user guide.

Only open refrigerator doors for necessary time.

Don’t allow air outlets to be obstructed.

See installation instructions.

Adapt them in accordance with instructions.

Adjust the levelling knobs.

See the installation instructions.

The variation in size of ice cubes is normal.

The access door is not being closed properly.

Refrigerator is exposed to direct heat or sunlight.

Door is being left open for excessive amounts of time.

The air circulation is obstructed.

It has been installed in an unsuitable place.

The accessories are not well positioned.

The levelling is not adequate.

It has been installed in an unsuitable place.

Freezer duct or grille obstructed.

The water cylinder wasn´t filled up to the

maximum level.

Don’t add more water as this could spill out

and/or could mean more force will be required to

release the ice cubes.

The refrigerator is resting on a sloped floor,

and/or it itself is inclined. Thus, some ice-tray

cubes might not get fully filled. (The water

cylinder has the exact volume space for

water as the ice-tray.)

The refrigerator must have a certain incline

backwards. This may cause the ice-tray to lie

slightly unevenly.

Check that there aren’t any objects or foods

obstructing the air-way in the freezer´s air flow

grille (grille at the front of the compartment).

It is normal for atmospheric humidity to be higher

than 75%.

Check that there aren’t any objects inside the

access door keeping it from closing.

Elevated humidity in the atmosphere

(higher than 75 % RH).

The knob on the exterior temperature display

has been incorrectly set.

On high temperature and high humidity

enviroments your refrigerator may show

condensation on the acces door.

This is a normal condition in the performance

of the unit. Sweep it with a dry cloth

whenerver you feel it is needed.

Ice-tray hasn´t

been filled to

maximum

capacity

Smart Fill Ice

Factory - When

filling the cylinder,

water spills out

from the lower

part where the

valve is.

Smart Fill Ice

Factory - It has

become difficult

to open water

cylinder lid

Smart Fill Ice

Factory won’t

release ice

Clean the ice accumulation with tepid water.

Clean with a soft sponge.

The valve was obstructed by ice.

The ice-tray has an excess of scale.

The programme has an in-built system to

prevent over-filling and ice sticking.

The lid of the cylinder has not been properly

closed.

Water has spilt onto the lip area of the cylinder

or this has been filled to excess. Ice has been

generated, impeding the opening of the lid.

You aren’t giving it that extra pull to twist

the ice-tray.

The cylinder hasn’t been positioned correctly, and

the ice-trays can´t be filled with water.

Take out the cylinder and fill it up to maximum

capacity.

Check that the tray doesn’t have ice stuck to it, or
that there isn’t an excess of water.

Press the lid of the cylinder in the middle.

Remove ice residue, which may be near the valve,

with tepid water.

Pull the handle more firmly until completely

twisting the tray.

Pour water into the cylinder again. Make sure that

the cylinder has been positioned properly by

watching for water falling into the trays.

Advertising