Summit PRO24G User Manual

Page 19

Advertising
background image

2. Remove the knob from the gas tap.
3. Use an appropriately sized

screwdriver to adjust the flow rate
adjustment screw.

For LPG (butane – propane), turn the
screw clockwise.
For natural gas, turn the screw counter-
clockwise once.
NOTE: The normal height of a straight
flame in the reduced position is about
1/4 inch.
4. If the flame is higher than the desired

position, turn the screw clockwise. If
it is smaller, turn counter-clockwise.

5. For the last control, bring the burner

both to high-flame and reduced
positions and check whether the
flame is on or off.

Depending on the type of gas tap used
in your appliance, the adjustment screw
position may vary.














Exchange injector for the broiler
1. Open broiler door.
2. Unscrew fastening screw of the

burner.

3. Slightly pull the broiler burner (1) to

lift it free with its link(s) on the rear
side connected.

4. Unscrew injector by turning in

counter-clockwise direction (3).

5. Fit new injector.






1 Broiler burner
2 Injector holder
3 Injector


Exchange injector for the oven
1. Unscrew fastening screws on the

back wall.














18

Advertising
This manual is related to the following products: