The gas power vent systems is designed to allow the installation of a gas appliance when typical vent confi gurations (shown in this manual) are not
possible.
Note: Must be terminated horizontally. Vertical terminations are not permitted.

Maximum total vent length = 60' maximum of six - 90° elbows permitted.
One 90° elbow = two 45° elbows.
Maximum total negative vent length = 10'.

VENTING ARRANGEMENTS FOR HORIZONTAL TERMINATIONS

(RIGID PIPE 5" X 8" - MUST USE REDUCER #946-606 & RIGID PIPE ADAPTOR # 770-994)