Regency Horizon HZ54EPV Gas Fireplace

27

INSTALLATION

of

14) Reverse steps 6-1 to complete installation.

15) Plug in Power Vent Module to outlet located on the lower left base of

the unit.

10) Tighten up the strain relief grommets on the outside of the box as

shown below.

11) Secure the ground wires from each wire bundle (BX cable + power

vent) to the box in the location shown below.

12) Connect all like colored wires - blue to blue, red to red, white to white

and black to black. Finish wire ends with marettes as shown below.

Ground

13) Install the cover on the electrical junction box-secure with 2 screws.

9) Feed wires from the BX cable through into the box.

Caution: Label all wires prior to disconnection when

servicing controls.

Wiring errors can cause improper and dangerous

operation.

Advertising