Installation, Power vent terminal installation – Regency Horizon HZ54EPV Large Gas Fireplace User Manual

Page 23

Advertising
background image

Regency Horizon HZ54EPV Gas Fireplace

23

INSTALLATION

11-3/4”

11-3/4”

Determine

the correct

height

WARNING:

ELECTRICAL CONNECTIONS SHOULD ONLY BE

CARRIED OUT BY A QUALIFIED AND LICENSED

ELECTRICIAN

POWER VENT TERMINAL INSTALLATION

Note: Optional 5 wire BX cable comes in 20' or 60' lengths as required.

Wires are color coded for ease of installation.

1) Frame in opening for the Power Vent Terminal by fi rst determining the

correct height - frame in an 11-3/4" x 11-3/4" opening.

3) Install the Power Vent outer frame with 4 screws - screw locations

shown below.

Important: Orient the frame so the BX cable will pass through in the lower

left corner.

4) Remove the plate from the bottom right corner of the frame by removing

2 screws from the inside of the frame.

5) Install a strain relief grommet through the plate as shown below.

6) Unravel the BX cable - to expose approx. 7" of wire. Install a wire

protector where the metal of the BX cable and the wire meet.

7 ) Feed a length of BX cable through - (approx. 18") the plate and tighten

the strain relief grommet to the plate.

2) Feed the BX cable through the fi restop - ensure protective grommet is in

place before feeding the cable through.

Protective grommet

Wire protector

Strain Relief

Firestop