Weidmuller DC/DC CCC HF - with 3 way separation User Manual
Page 3

12
13
3.4 Labelling possibilities
(s. Fig. 4)
WS 10 connector markers can be used to label module.
4
Electrical connection
(s. Fig. 5)
Cat. No. 8447160000
(s. Fig. 6)
Cat. No. 8447280000
5
Dimensions
(s. Fig. 7)
6
Notes on CE labelling of WAVESERIES modules
WAVESERIES modules, that carry CE-labelling, fulfil the requirements
of the EU-Guidelines 89/336/EU "electromagnetic compatibility" and
the therein listed harmonised European Norms (EN).
The declarations of conformity are, in accordance with the above-
mentioned EU-Guideline, Article 10, held at the following address
for the relevant authorities:
Weidmüller Interface GmbH & Co.
Postfach 3030
32720 Detmold
7
Technical data
Input
Input signal
0 ... 20 mA or 4 ... 20 mA
0 ... 10 V or -10 ... +10 V
Input voltage, max.
± 15 V (0 ... 10 V, -10 V…+10 V)
Input current, max.
50 mA (0 ... 20 mA, 4 ... 20 mA)
Input resistance
50
Ω (0 ... 20 mA, 4 ... 20 mA)
500 k
Ω (0 ... 10 V)
Output
Output signal
0 ... 20 mA or 4 ... 20 mA
0 ... 10 V or -10 ... +10 V
Load resistance
≤ 500 Ω (0 ... 20 mA, 4 ... 20 mA)
≥ 2 kΩ (0 ... 10 V)
Accuracy by T
u
= 23 °C
± 0.2 % from measuring range