Weidmuller DC/DC CCC HF - with 3 way separation User Manual

Page 3

Advertising
background image

12

13

3.4 Labelling possibilities

(s. Fig. 4)

WS 10 connector markers can be used to label module.

4

Electrical connection
(s. Fig. 5)

Cat. No. 8447160000

(s. Fig. 6)

Cat. No. 8447280000

5

Dimensions
(s. Fig. 7)

6

Notes on CE labelling of WAVESERIES modules

WAVESERIES modules, that carry CE-labelling, fulfil the requirements
of the EU-Guidelines 89/336/EU "electromagnetic compatibility" and
the therein listed harmonised European Norms (EN).

The declarations of conformity are, in accordance with the above-
mentioned EU-Guideline, Article 10, held at the following address
for the relevant authorities:

Weidmüller Interface GmbH & Co.
Postfach 3030
32720 Detmold

7

Technical data

Input
Input signal

0 ... 20 mA or 4 ... 20 mA
0 ... 10 V or -10 ... +10 V

Input voltage, max.

± 15 V (0 ... 10 V, -10 V…+10 V)

Input current, max.

50 mA (0 ... 20 mA, 4 ... 20 mA)

Input resistance

50

Ω (0 ... 20 mA, 4 ... 20 mA)

500 k

Ω (0 ... 10 V)

Output
Output signal

0 ... 20 mA or 4 ... 20 mA

0 ... 10 V or -10 ... +10 V

Load resistance

≤ 500 Ω (0 ... 20 mA, 4 ... 20 mA)

≥ 2 kΩ (0 ... 10 V)

Accuracy by T

u

= 23 °C

± 0.2 % from measuring range

Advertising