Rockwell Automation 40BY1 Miniature End View Transmitted Beam Control User Manual

Installation instructions photoswitch

Advertising
background image

INSTALLATION INSTRUCTIONS

PHOTOSWITCH

MINIATURE END VIEW

TRANSMITTED BEAM CONTROL, BULLETIN 40BY1/47BU1- 4000

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE. FOR ADDITIONAL INFORMATION REFER TO PUBLICATION PG-9000

BULLETIN NUMBER

TYPE

RESPONSE TIME

OPERATING DISTANCE

22DJ3--4000

22DJ4--4000

22DJ9--4000

22DJ9--4001

22DJ4--5000

22DJ9--5000

40BY1--4000

+

47BU1--4000

Light Source

Refer to

22 Series 4000

or

22 Series 5000

2 (.61m)

5 (1.52m)

3 (.90m)

Receiver

With 63--70 Range Extender

10 (3.05m)

25 (7.62m)

40BY1--4000

+

47BU1--4000

+

63--70

Diffuse

6 (.15m)

12 (.3m)

SPECIFICATIONS
Field of View

7.5

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Transmitting LED

Infrared, 940nm

. . . . . . . . . . . . . . . . . . . . . . . .

Ambient Temperature Range

--40F to 185F (--40C to 85C)

. .

Approvals

UL Listed and CSA Certified

. . . . . . . . . . . . . . . . . . . .

Operating Environment

NEMA 3, 4, 12, 13 and IP66 (IEC529)

. .

Housing

High impact chemically resistant Housing

. . . . . . . . . . . .

Cable

Light Source

2 conductor vinyl jacketed cable 10 (3m)

. . . . . . .

Receiver

2 conductor vinyl jacketed cable 10 (3m)

. . . . . . . . . .

OPERATING DISTANCE SELECTION

The maximum operating distance is based on installing the control

in a relatively clean environment. Normal industrial environment ac-
tually ranges from moderately dusty to extremely dirty. Greater oper-
ating margin (excess gain) may be required, which can be obtained by
reducing the operating distance of the control. (optics should be
cleaned regularly.)

TYPICAL RESPONSE CURVE

10%

20%

30%

40% 50%

100%

Percent of Maxium Operating Range

T

2

T

1

Recommended Operating

Range Derating For “dirty”

Industrial Environments

Recommended Operating Range

Derating For “normal” Industrial

Environments

100X

50x

40x
30x

20x

10x

5x

4x
3x

2x

1x

Transmitted Beam Operating

Range Selection

OP

ERA

TIN

G

M

AR

GIN

INSTALLATION

The control must be securely mounted on a firm, stable surface or

support. A mounting which is subject to excessive vibration or shift-
ing may cause intermittent operation.

45

0

1/2R

(12.7)

.196 (5)

SLOT

13/64 (5.16)

DIA. HOLE

17/32

(38.9)

23/32

(18.3)

23/32

(18.3)

1 1/8

90

0

UNIVERSAL MOUNTING ASSEMBLY #61--4847

Advertising