WIRING

All external wiring should conform to The National Electric Code

and applicable local codes. See wiring diagrams for external connec-
tions. For maximum electric shielding, rigid conduit is recommended
for extensions of scanner wiring. DO NOT RUN PHOTODETEC-
TOR WIRES AND LINE VOLTAGES IN THE SAME CONDUIT.

WIRING DIAGRAMS

1
2

3
4

8
7

0
5

PLUG-IN

CONTROL MODULE

SERIES 4000 LED

CONTROL BASE ONLY

BLK

RED

47BU1 RECEIVER

SHIELD WIRE SHOULD

BE INSULATED BY USER

RED

WHT

40BY1 LED SOURCE

Notes:

1. Receiver housing must always be grounded.

2. Do not ground light source shield or terminal 4.

3. Receiver housing is connected internally to its cable

shield, so shield will be automatically grounded.

4. Light source housing is not connected internally to its

cable shield. It may be grounded, but is not required.

47BU1--4000 AND 40BY1--4000

OPEN COLLECTOR (NPN) CURRENT SINK

OUTPUT TO POWER EXTERNAL LOADS

OR TO #61--2124 OUTPUT BASE

L1

L2

OUT

1
2
3

SERIES

5000

#60--2120 BASE

120VAC

RECEIVER

LED SOURCE

BLK

RED

RED

WHT

CONNECT ALL SHIELDS TO TERMINAL PS (--)

PS( --)

WITH UNIVERSAL FUNCTION BASE #60--2120

OUT

1
2

3

PS (--)

SERIES

5000

PS (+)

PS (--)

OUT

1

( + )

( -- )

24VDC

#60--2123

OPEN COLLECTOR (NPN) CURRENT SINK

OUTPUT TO POWER EXTERNAL LOADS

OR TO #61--2124 OUTPUT BASE

OUTPUT

RECEIVER

BLK

RED

#60--2123 BASE

CONNECT ALL SHIELDS TO TERMINAL PS (--)

RED

WHT

LED SOURCE

WITH MULT--MODULE FUNCTION BASE #60--2123

ALIGNMENT

Set the amplifier to the light operate mode. Adjust the sensitivity

to the maximum setting, turning the sensitivity potentiometer clock-
wise. Aim the light source at the receiver until the alignment indicator
on the amplifier turns on.

To be certain that the beam is centered, sweep the receiver at the

light source in the horizontal plane and determine the position where
the alignment indicator turns on and then off. Do the same in the verti-
cal plane. Set the beam halfway between both positions.

It may be necessary to reduce the sensitivity to a lower setting for

transparent or translucent materials or to detect objects smaller that
the effective beam.

DIMENSIONS

.38

(9.5)

ACROSS FLATS

1.85

(47.0)

.68

(17.3)

.12

(3.0)

.25

(6.35)

SWIVEL WASHER (2)

1

/

4

- 28 HEX NUT (2)

LED INDICATOR ON

40BY1 ONLY

Publication PA--9198(A)

November 1992

Supercedes Publication PA--8727

Advertising