PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board
9
12. Disconnect the cables from connector XCD and XUVW on the Pulse
Transformer circuit board.
13. Cut the cable ties that secure all cables connected to the Transient Noise
Filter board and remove the board and cables from the drive.
Step 4: Install the New
Transient Noise Filter Board
Install the new Transient Noise Filter and existing Power Supply Filter
boards in reverse order of removal as detailed in Step 3:
Existing Transient Noise Filter Board on page 4