PowerFlex 700 Adjustable Frequency AC Drive – Frames 0…6

Table 11 - Abbreviated Alarm Listing

Alarm

No.

Ty

p

e

(1

)

(1) See the User Manual for a description of alarm types.

Description

Dig In
ConflictA

17

➁

Digital input functions are in conflict. Combinations marked with a “ ” cause an alarm.

Dig In
ConflictB

18

➁

A digital Start input has been configured without a Stop input or other functions are in conflict.
Combinations that conflict are marked with a “ ” and cause an alarm.

Dig In
ConflictC

19

➁

More than one physical input has been configured to the same input function. Multiple
configurations are not allowed for the following input functions.
Forward/Reverse

Run Reverse

Bus Regulation Mode B

Speed Select 1

Jog Forward

Acc2 / Dec2

Speed Select 2

Jog Reverse

Accel 2

Speed Select 3

Run

Decel 2

Run Forward

Stop Mode B

TB Man
Ref Cflct

30

➁

Occurs when:
• “Auto/Manual” is selected (default) for [Digital In3 Sel], parameter 363 and
• [TB Man Ref Sel], parameter 96 has been reprogrammed.
No other use for the selected analog input can be programmed.
Example: If [TB Man Ref Sel] is reprogrammed to “Analog In 2,” all of the factory default uses
for “Analog In 2” must be reprogrammed (such as parameters 90, 117, 128 and 179). Refer to
the Auto/Manual Examples section of the PowerFlex 700 User Manual.
To correct:
• Verify/reprogram the parameters that reference an analog input or
• Reprogram [Digital In3] to another function or “Unused.”

Acc2/Dec2

Accel 2

Decel 2

Jog 1/2

Jog Fwd

Jog Rev

Fwd/Rev

Acc2/Dec2

Accel 2

Decel 2

Jog 1/2

Jog Fwd

Jog Rev

Fwd/Rev

Start

Stop-CF

Run

Run Fwd

Run Rev

Jog 1/2

Jog Fwd

Jog Rev

Fwd/Rev

Start

Stop-CF

Run

Run Fwd

Run Rev

Jog 1/2

Jog Fwd

Jog Rev

Fwd/Rev

Advertising