Rockwell Automation 20P PowerFlex DC Drive - Frame B Field Dual Diode Module User Manual

Page 7

Advertising
background image

PowerFlex® DC Drive - Frame B Field Dual Diode Module

7

6. Carefully disconnect the cables from connectors XA, XR and XFCD at

the top of the Control board.

7. Loosen the two captive screws at the top of the Control EMI shield and

lower the shield.

Important: If the drive is not in a vertical position, the Control EMI

shield will not remain open without a means of restraint.

8. Remove the two screws that secure the air flow plate to the top of the

Pulse Transformer board and lift the plate off the drive chassis. The air
flow plate cannot be completely removed due to the fuse connections at
FU1 and FV1.

Disconnect
cables

Loosen screws

Remove screws

Fuse connections

Advertising