Rockwell Automation 22A PowerFlex 4 Custom Firmware - DA Option User Manual

Powerflex 4 custom firmware, Overview, About parameters

Advertising
background image

Overview

The purpose of this insert instructions manual is to provide the special information about
the custom firmware version 51.xx (indicated by parameter D016).

This custom firmware option adds support for the maximum output frequency [Drive
Speed] up to 300 Hz, and fast stop DC braking function.


About Parameters

Compared to the standard firmware, the custom firmware has included the following new
parameters and modified the following standard parameters.


P032 [Motor NP Hertz]

Values

Default 60

Hz

Min/Max:

10/300

Hz

Display:

1

Hz

ATTENTION:

The Custom Firmware supplied is designed for a

specific application and load condition. It differs from the standard
PowerFlex4 product offering and must be installed and run only under
this custom application. Attempting to run this Custom Firmware under
any other type of applications, could result in unpredictable and/or
hazardous conditions.

PowerFlex 4 Custom Firmware

“DA” Option – 300Hz Maximum Frequency and Quick Stop

ATTENTION:

The drive contains ESD (Electrostatic Discharge)

sensitive parts and assemblies. Static control precautions are required
when installing, testing, servicing, or repairing this assembly.
Component damage may result if ESD control procedures are not
followed. If you are not familiar with static control procedures, reference
A-B publication 8000-4.5.2, “Guarding Against Electrostatic Damage”
or any other application ESD protection handbook.

Advertising