P034 [Minimum Freq]

Values

Default 0.0

Hz

Min/Max:

0.0/300.0

Hz

Display:

0.1

Hz


P035 [Maximum Freq]

Values

Default 60

Hz

Min/Max:

0/300.0

Hz

Display:

1

Hz


A069 [Internal Freq]

Values

Default 60.0

Hz

Min/Max:

0.0/300.0

Hz

Display:

0.1

Hz

A070 [Preset Freq 0]
A071 [Preset Freq 1]
A072 [Preset Freq 2]
A073 [Preset Freq 3]

Values

A070 Default
A071 Default
A072 Default
A073 Default

0.0 Hz
5.0 Hz
10.0 Hz
20.0 Hz

Min/Max:

0.0/300.0

Hz

Display:

0.1

Hz


P042 [DC Brk Pressure] – New Parameter
This is the new parameter, which affects the DC braking performance.

Values

Default 1200

Min/Max:

80/2000

Display:

1

A109 [Ground Fault Avoid] – New Parameter
This is a new parameter, which can be used to avoid the ground fault F13.

Values

Default 0

Min/Max:

0/2

Display:

1