Rockwell Automation 56RF RFID Square 40x40 mm Transceiver Installation Instructions User Manual
Page 2

Drwg. No. 10000181821 Ver 01
March 2012
Printed in USA
LED Illumination Pattern
Connector Pinout
Frequently Asked Questions
Reference the product manuals for more specific installation
and configuration information. Manuals are available at
www.ab.com/rfid
.
Approximate Dimensions – mm (in.)
Dimensions are not intended to be used for installation purposes.
LED Display
Content
Module Status
LED
Green light
Power ON
No illumination
No power
Read/Write
LED
Green light
Normal operation
Flashing green (short interval)
Communicating
Flashing amber (short interval)
Sensing tag
Flashing red (long interval)
Communication error
Flashing green (long interval)
No tag
Pin
Signal
1
24V DC
2
Data +
3
GND
4
Data -
IMPORTANT: Installation of Allen-Bradley products should be in
accordance with local and/or national codes. Servicing
energized industrial control equipment can be hazardous if
not in accordance to recommended safety procedures.
4
3
1
2
5.4
(0.21)
12
(0.47)
30
(1.18)
30
(1.18)
46 (1.81)
40 (1.57)
7.5 (0.3)
40
(1.57)
40
(1.57)
73.5 (2.89)