Parameter List

Parameter
No. Name and Description

Details

01

[Startup Display]

Selects the display screen shown when the HIM is powered up.

Default:

0 = Main Menu

Values

0 = Main Menu
1 = Process Disp
2 = Large Disp
3 = Startup Param

Type:

Read/Write

02

[Startup Param]

Selects a desired drive parameter to be displayed if Parameter 01 -
[Startup Display]
is set to “3” (Startup Param).

Default:

1

Minimum: 1
Maximum: 65535
Type:

Read/Write

03

Reserved

04

[User Disp Line 1]

Selects a desired drive parameter to be displayed on User Display
Line 1 of the Process Display screen.

For example, setting to “3” selects PowerFlex 4-Class drive
Parameter 3 - [Output Current] to be displayed.

Default:

3

Minimum: 1
Maximum: 65535
Type:

Read/Write

05

[User Disp Line 2]

Selects a desired drive parameter to be displayed on User Display
Line 2 of the Process Display screen.

For example, setting to “5” selects PowerFlex 4-Class drive
Parameter 5 - [DC Bus Voltage] to be displayed.

Default:

5

Minimum: 1
Maximum: 65535
Type:

Read/Write

06

[Large Disp Param]

Selects a desired drive parameter to be displayed on the Large
Format User Display screen.

For example, setting to “1” selects PowerFlex 4-Class drive
Parameter 1 - [Output Freq] to be displayed. Setting to “0” enables
the Scaled Reference to be displayed.

Default:

1

Minimum: 0
Maximum: 65535
Type:

Read/Write

07

[LCD Contrast]

Sets the HIM LCD contrast level.

Default:

50%

Minimum: 0%
Maximum: 100%
Type:

Read/Write

08

[Reset HIM]

1 (Reset):

Resets the HIM.

2 (Set Defaults): Resets HIM parameters to factory settings.

This parameter returns to a value of “0” (Ready) after the reset
function is complete.

Default:

0 = Ready

Values

0 = Ready
1 = Reset
2 = Set Defaults

Type:

Read/Write

09

[Device Type]

Selects the HIM device type. When set to “0” (Auto), the HIM is
automatically configured as either a DSI Master or Slave depending
on the presence of other peripheral devices.

Default:

0 = Auto

Values

0 = Auto
1 = Slave
2 = Master

Type:

Read/Write

10

[M/S Status]

Displays the HIM active device type.

Default:

N/A

Values

1 = Slave
2 = Master

Type:

Read Only

11

[HIM Ref Preset]

0 (Zero Start):

HIM Reference is always “0.0” at power on.

1 (Host Output): HIM will assume the Host’s output feedback

(bumpless transfer) and preset its Reference when
the Reference is configured to be received on the
RS-485 port. This can be verified by viewing
Diagnostics/Device Status/Remote Freq Ref = 1.

2 (Last HIM Ref): HIM will store the HIM Reference in EEPROM each

time it is changed. HIM Reference is restored at
power on.

Default:

0 = Zero Start

Values

0 = Zero Start
1 = Host Output
2 = Last HIM Ref

Type:

Read/Write