Rockwell Automation 20P PowerFlex DC Drive - Frame D Field Fuse Holder Replacement User Manual

Page 2

Advertising
background image

Publication 20P-IN070A-EN-P

2

1. Remove and lock-out all incoming power to the drive.

2. Loosen, but do not remove, the four hexalobular screws that secure the top

control pan cover to the drive, then slide the cover up and off the drive
chassis. Tightening torque is noted in the illustration for reassembly.

3. Disconnect the DPI cable from the HIM assembly (if present).

Important: A communication cable connects the HIM assembly to the

Control board mounted on the control pan. Therefore, the
bottom control pan cover and HIM assembly cannot be fully
removed from the drive until the cable is disconnected. Step 4
details this connection.

4. Loosen, but do not remove, the four hexalobular screws that secure the

bottom control pan cover to the drive, then slide the cover up and off the
drive chassis. Tightening torque is noted in the illustration for reassembly.

L1

L2

L3

O

I

Top control
pan cover

Bottom control
pan cover

Tightening torque:
1.5 N•m (13 lb•in)

T15

=

Disconnect
DPI cable

Advertising