Dimensions—mm (inches) wiring diagram – Rockwell Automation 45BPD Analog Laser Sensor User Manual

Page 3

Advertising
background image

3

The Installation Instructions should be read and understood before operating the sensor.

The 45BPD sensor should only be installed by qualified personnel.

The 45BPD is not a safety component as described by EU machine directives.

The 45BPD is a Class 2 laser product. There is a natural eye aversion when looking into the laser beam. Do not
look directly into the laser beam or suppress the reflex to close your eyes.

The 45BPD should be mounted such that it is not directed at people (head height) and the beam path is
terminated at the end of its functional path.

The laser safety label on the 45BPD sensor should be visible after installation. A second label has been provided in
the event that the attached label is covered due to the installation.

Dimensions—mm (inches)

Wiring Diagram

The control input (pin 5) can be used to disable the laser by connecting it to the +DC power supply (18…30V
DC). The laser is shut down and both the discrete and analog outputs will retain their state. The control input (pin
5) can also be used to prevent setting changes to the sensor (lock out the Teach-in buttons) by connecting it to 0V
DC. The sensor can be operated in the free-run mode by not connecting the control input (pin 5).

Laser Light

Do not stare into beam

class 2 laser product

EN60825-1, 03/97,

λ=630…680 nm

pulsed - mode operation

50 (1.97)

50

(1.97)

40 (1.57)

44 (1.73)

16 (0.63)

13.5 (0.53)

46

(1.81)

44

(1.73)

17

(0.67)

4.3

(0.17)

4 (0.16)

4 (0.16)

4.3 (0.17)

4 (0.16)

M12 x 1

Allen-Bradley

5

2

1

3

4

(1) Brown

(2) White
(3) Blue

(4) Black

(5) Grey

18…30V DC
4…20 mA
0V
Switch output

Control input

Advertising