Step 1: Remove Power
from the Drive
1. Remove and lock-out all incoming power to the drive.
Step 2: Remove the
Protective Covers
1. Disconnect the DPI cable from the HIM assembly (if present).
2. Loosen, but do not remove, the screws that secure the bottom cover to
the drive, then slide the cover down and off the drive chassis.
!
ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur. An electrical arc can
cause personal injury or property damage by:
•
sending an erroneous signal to your system’s field devices,
causing unintended machine motion
•
causing an explosion in a hazardous environment
Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.
L1
L2
L3
O
I
STS
PORT
MOD
NET A
NET B
Disconnect
DPI cable
=
Tightening torque:
1.5 N-m (13.3 lb.-in.)