What this kit includes, Tools that you need, What you need to do – Rockwell Automation 20P PowerFlex DC Drive Frame D Series A to Series B Fan Replacement User Manual

Page 2

Advertising
background image

2

Rockwell Automation Publication 20P-IN074A-EN-P - October 2014

PowerFlex DC Drive Frame D Series A to Series B Fan Replacement

What This Kit Includes

Fan assembly (includes fan and mounting bracket)
A portion of the data nameplate label with the new three-phase fan loss

detection board terminal names

Three-phase fan loss detection board and support
Top air flow plate

Tools That You Need

T20 hexalobular screwdriver
T10 hexalobular screwdriver
13 mm socket wrench
Cable ties
Wire cutter
3.5 mm x 0.8 mm screwdriver

What You Need to Do

To replace the existing fan assembly:

Step 1: Remove power from the drive
Step 2: Remove the protective cover and top air flow plate
Step 3: Remove the existing fan assembly
Step 4: Remove the existing fan loss detection board
Step 5: Remove the existing fan starting capacitor
Step 6: Install the series B three-phase fan loss detection board
Step 7: Install the series B top air flow plate
Step 8: Replace the top protective cover and document the change

IMPORTANT

The Frame D, series B drive cooling fan requires three-phase (50/60 Hz),
400…460V AC input power. If sourced from the main three-phase AC input,
the power supply connections must be taken from the primary side of the
installed isolation transformer or line reactor (clean power).