Rockwell Automation 20P PowerFlex DC Drive - Frame C Switching Power Supply Circuit Board User Manual
Page 6
Advertising
6
PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board
3. Disconnect the cable from connector XSW on the Switching Power
Supply board (see
for location) and lower the
Control EMI shield until it rests on the drive chassis.
Important: If the drive is not in a vertical position, the Control EMI
shield will not stay open without a means of restraint.
4. Disconnect the cables from connector XA and XUV on the Switching
Power Supply board (see
5. If present, disconnect the jumper from terminals SA-SB (see
for location).
Important: Be sure to replace the jumper between terminals SA-SB if
using 115V AC control input power when installing a new
Switching Power Supply board.
Remove cable
Disconnect cables and wiring
Advertising