Rockwell Automation 20P PowerFlex DC Drive - Frame C Switching Power Supply Circuit Board User Manual

Page 6

Advertising
background image

6

PowerFlex® DC Drive - Frame C Switching Power Supply Circuit Board

3. Disconnect the cable from connector XSW on the Switching Power

Supply board (see

Figure 1 on page 5

for location) and lower the

Control EMI shield until it rests on the drive chassis.

Important: If the drive is not in a vertical position, the Control EMI

shield will not stay open without a means of restraint.

4. Disconnect the cables from connector XA and XUV on the Switching

Power Supply board (see

Figure 1 on page 5

for location).

5. If present, disconnect the jumper from terminals SA-SB (see

Figure

1 on page 5

for location).

Important: Be sure to replace the jumper between terminals SA-SB if

using 115V AC control input power when installing a new
Switching Power Supply board.

Remove cable

Disconnect cables and wiring

Advertising