Step 4: install the new scr module leg assemblies – Rockwell Automation 20P PowerFlex DC Drive - Frame D SCR Module Leg Assembly User Manual

Page 8

Advertising
background image

Publication 20P-IN054A-EN-P

8

11. If you are reusing the bimetal thermostat mounted on the left SCR module

leg assembly, disconnect the wires from the connector mounted on the
middle, left-side of the assembly.

12. Remove the two hexalobular screws that secure the thermostat to the heat

sink and remove the thermostat.

Step 4: Install the New
SCR Module Leg
Assemblies

• Install the new SCR module leg assemblies in the reverse order of removal as

detailed in Step 3:

Remove the Existing SCR Module Leg Assemblies on

page 4

.

Important: Apply thermal grease to the bottom of the bimetal thermostat

before installation.

Tightening torque for the bimetal thermostat is 1.0 N•m (8.9 lb•in).

Tightening torque for the SCR module leg assemblies is 4.5…5.0 N•m

(40.0…44.4 lb•in).

Tightening torque for the SCR module input and output terminals to the

fuse terminals and DC output bus bars is 45 N•m (398 lb•in).

Remove screws

Disconnect
wires from
connector

Advertising