Step 1: remove power from the drive – Rockwell Automation 20P PowerFlex DC Drive - Frame C Cooling Fan User Manual

Page 2

Advertising
background image

2

PowerFlex® DC Drive - Frame C Cooling Fan

Step 1: Remove Power
from the Drive

1. Remove and lock-out all incoming power to the drive.

Step 2: Remove the
Protective Covers and
Moving the EMI Shield and
Control Board

1. Disconnect the DPI cable from the HIM assembly (if present).

2. Loosen, but do not remove, the screws that secure the bottom cover to

the drive, then slide the cover down and off the drive chassis.

!

ATTENTION: Remove power before making or breaking cable
connections. When you remove or insert a cable connector with
power applied, an electrical arc may occur. An electrical arc can
cause personal injury or property damage by:

sending an erroneous signal to your system’s field devices,
causing unintended machine motion

causing an explosion in a hazardous environment

Electrical arcing causes excessive wear to contacts on both the
module and its mating connector. Worn contacts may create
electrical resistance.

L1

L2

L3

O

I

STS

PORT

MOD

NET A

NET B

=

Disconnect
DPI cable

Tightening torque:
1.5 N-m (13.3 lb.-in.)

Advertising