Rockwell Automation 20P PowerFlex DC Drive - Frame C Transient Noise Filter Circuit Board Fuse User Manual

Page 5

Advertising
background image

PowerFlex® DC Drive - Frame C Transient Noise Filter Circuit Board Fuse Replacement

5

9. Remove the three fuses from the fuse holders (F11, F21 and F31) on the

Transient Noise Filter board.

10. Insert the new fuses into the fuse holders on the Transient Noise Filter

board.

11. Lift the EMI Shield, connect the cable to connector XSW on the

Switching Power Supply board and secure the EMI Shield with the two
captive screws.

12. Connect the cables to connectors XFCD and XR on the Control board.

13. Connect the Communication cable from the HIM on the top Protective

Cover to the connector on the upper right corner of the Control board
and install the Protective Covers in the reverse order of removal.

14. Connect the DPI cable to the HIM (if present).

Remove fuses from holders

Advertising