Rockwell Automation 42D Series 5000 Blue Line with Analog Output User Manual

Installation instructions—photoswitch, Series 5000 blue line with analog output

Advertising
background image

1

Installation Instructions—PHOTOSWITCH

R

Series 5000 Blue Line with Analog Output

Photo Head

Retroreflective

Standard Diffuse

Fixed Focus

Wide Angle

Fiber Optic

Infrared Glass

Fiber Optic

Visible Red Plastic

Catalog Number

42DRU--5400

42DRP--5400

42DRA--5400--FF 

42DRF--5400--FF

42DRA--5400--WA 

42DRF--5400--WA

42DRA--5400--FO 

42DRF--5400--FO

Sensing Distance

4.6m (15ft) total

4.0m (13ft) linear

1.5m (5ft) total

1.2m (4ft) linear

(IR) 127mm (5in) max peak @ 3in

(VR) 101.6mm (4in) max peak @ 2in

(IR) 508mm (20in)

(VR) 177.8mm (7in)

Depends on fiber optic cable

Transmitting LED

Infrared 880nm

Infrared 880nm

(42DRA) Infrared 880nm (42DRF) Visible Red 660nm

Infrared 880nm

Visible Red 660nm

Indicators

Red: Setpoint A; Green: Setpoint B

Field of View

3_

3_

Depends on fiber optic cable selected

Sensitivity Adjustment

Yes

Operating Temperature

--40_C to +65_C (--40_F to +150_F)

Relative Humidity

90% maximum

Housing/Lens Material

Valox

/Acrylic

Valox

/Acrylic

Cover Gasket Material

Nitrile

Operating Environment

NEMA 3, 4, 12, 13, and IP66 (IEC 529), corrosion resistant, high-impact housing

Approvals

UL listed, CSA certified (except cable style power base), and CE marked for all applicable directives

Protections

Output short-circuit (analog only)

Vibration

10--55 Hz, 1 mm amplitude, Meets or exceeds IEC 947--5--2

Shock

30G, Meets or exceeds IEC 947--5--2

Supply Voltage/Current

22--28V DC/70mA max

Output Type

Analog 1--20mA current or 1--10V DC voltage (selectable negative or positive slope) (2) NPN setpoints (selectable)

Output Load

900 (analog current); 3K minimum (analog voltage); 28V DC, 100mA (setpoints)

Load Current

100mA

Leakage Current

10A max.

Response Time

100ms (time required for analog swing)

Photo Base

Screw Terminal (nickel-plated brass

pressure type terminal #6--32

42DTB--5000

3m Cable (5 conductor flexible PVC

jacketed cable 3m (10ft))

42DCB--5000

Sensing modes may be field configurable by selecting either the 42DRA--5400 or 42DRF--5400 photohead and one of the following lens assemblies: 61--5551 for fixed focus sensing mode, 61--5511 for wide angle diffuse sensing

mode.

Advertising