Installation

The 45MLD–8LEA1–P4 must be mounted to a firm stable
surface or support. A mounting, which is subject to excessive
vibrating or shifting may cause intermittent operation. For
installation convenience, we offer the following mounting
bracket (Catalog Number 60–2677).

100

(3.94)

54

(2.13)

4.8 (0.18) Dia.

76 (2.99)

27

(1.06)

21.1

(0.83)

28.7

(1.13)

4.8 (0.18) Dia.

41

(1.61)

45

(1.77)

1.9

(0.07)

Dimensions—mm (inches)

Laser

Optical Axis

60

(2.36)

4.1 (0.16) Dia.

Supply

Timer

Target

23

(0.90)

54

(2.12)

18

(0.70)

9

(0.35)

60

(2.36)

6

(0.23)

(Norm)

Range

Adjustment

Wiring Diagrams

+

1

2

4

3

Brown

White

Black

Blue

Load

Pico

NPN (Light Operate)

NPN (Dark Operate)

Ê

PNP (Light Operate)

+

1

2

4

3

Brown

White

Black

Blue

Load

Ê

+

PNP (Dark Operate)

+

1

2

4

3

Brown

White

Black

Blue

Load

Pico

Ê

+

1

2

4

3

Brown

White

Black

Blue

Load

К

+

1

3

2

4

1

3

2

4

К 40ms off delay timer “Active” = Tie White Wire to (+) positive terminal.

40ms off delay timer “Inactive” = Open circuit or tie White Wire to (–) negative terminal.