Multipulse Bridge Assembly Parts Kits
7
Replacing the Fan(s)
To replace the fan(s), follow these steps:
1. Remove the red 115V power supply and white neutral wires from the
stab-on connectors on the fan.
2. Using a thin, standard screwdriver, remove the screws and lockwashers
that secure the fan.
3. Remove the fan and fan spacer.
4. Put the new fan in place, making sure that you align the holes in the
bridge with the holes in the four corners of the fan and fan spacer.
Important: Make sure that the arrows on the fan are pointing towards
the top of the cabinet.
5. Start the screws and lockwashers in the four corners.
6. Tighten the screws to 1.36 N–m (12 lbs.–in.).
7. Attach the red power supply and white neutral wires to the stab-on
connectors on the fan.
!
ATTENTION: Disconnect and lock out power from the system
before disassembling the drive. Failure to disconnect power may
result in death or serious injury. Verify bus voltage by measuring
the voltage between +DC and –DC on terminal block TB1 which
is located at the bottom of the 1336 Drive in the Inverter Bay. Do
not attempt to service the drive until the bus voltage has
discharged to zero volts.
Fan
Fan Spacer
Air Flow
Fan Wires