Converter thermal switch replacement kit, Where this kit is used, What this kit contains – Rockwell Automation 1336S_E Drive Multipulse Bridge Assembly User Manual
Page 8: Locating the thermal switches
 
8
Multipulse Bridge Assembly Parts Kits
Converter Thermal Switch 
Replacement Kit
Where This Kit Is Used
Converter Thermal Switch Replacement (Catalog Number 
1336-TR-SP8A) - You can use this kit to replace the thermal switch(es) that 
are located on the multipulse bridge assembly in the converter bay of your 
1336 PLUS II Multipulse or H-Frame IMPACT drive.
Table 5. Thermal Switch Part Numbers
What This Kit Contains
This kit contains a replacement thermal switch and these instructions.
Locating the Thermal Switches
The thermal switches are mounted on the bridge heatsink located in the 
converter bay of your drive.
Important: On some drive models the thermal switch may be located 
remotely at the top of the heatsink above the bus bars as shown in the 
following illustration. In cases where the thermal switch is mounted 
remotely it will not be necessary to remove the “AK” input terminals or bus 
bars for access to the switch.
Replacement Kit #
Vendor #
1336 - TR- SP8A
16283
Fan
Remote
Thermal
Switch(es)
Location
Internal Mount
Thermal
Switch(es)
Location