Technical Specifications

Safety Ratings

Standards

IEC/EN61496 Parts 1 and 2, UL61496 Parts 1 and 2, UL1998

Safety Classification

Type 4 per IEC/EN61496. Category 4 device per EN 954-1, SIL 3 per IEC 61508, PLe per EN/ISO 13849-1

Probability of a Dangerous Failure per Hour PFH

6.0 E-9 1/h MSR42 or MSR41 and MSR45E
4.0 E-9 1/h Micro 400

Certifications

cULus Listed, TÜV, CE Marked for all applicable directives

Outputs

Micro 400 Outputs

Data output to controller (MSR41 or MSR42)

MSR41/MSR42 Outputs

Two 400 mA OSSD

Non-Safety Outputs

Auxiliary outputs from MSR41 or MSR42 controller—2 configurable 100 mA, outputs

Switching Current @ Voltage, Max.

400 mA @ 24V DC

Operating Characteristics

Response Time

14 mm: 12…42 ms, varies by protective height and resolution, protect. height 150-1200 mm
30 mm; 11…23 ms, varies by protective height and resolution, protect. height 150-1200 mm

Indicator LEDs

ON -State, OFF-State, Intensity, Lockout

Protected Height [mm (in.)]

150…1200 (5.9 …47.2) in 150 mm increments

Resolution [mm (in.)]

14 (0.55), 30 (1.18) or PAC (Perimeter)

Scanning
Range/Resolution

14 mm (0.55 in.) resolution: 0…5 m (16.4 ft)
30 mm (1.18 in.) resolution: 0…5 m (16.4 ft)

Synchronization

Electrical through MSR41 or MSR42

Wave Length

940 nm

Time for Self Check When Switching on U

sp

< 5 s

Environmental

Enclosure Type Rating

Micro 400 is IP54;
Micro 400 IP69K is IP65, IP66, IP67, IP68, IP69K, Plug: IP65

Relative Humidity

15…95% (noncondensing)

Operating Temperature

0…55 °C (14…131 °F)

Storage Temperature

-20…70 °C (4…158 °F)

Vibration

IEC 60068-2-6; Frequency 10…55 Hz; Amplitude 0.35 mm (0.01 in.)

Shock

IEC 60068-2-29; Acceleration 10 g, pulse duration 16 ms 10…55 Hz;
Amplitude 0.35 mm (0.01 in.)

Power Supply

Input power from MSR41 or MSR42 controller

Input Power, Max.

24V DC ±15%

(MSR41 or MSR42 controller)

Maximum Residual Ripple

5% of Vss

Power Consumption

0.07 A max. (no load)

Equipment Class

III (VDE 0106 part 100)

EMC

IEC 61496 part 1

Physical Characteristics

Max. Number of Beams

255

Standard Mounting

180° adjustable mounting brackets supplied

(two sets 445L-AF6143)

Weight

Varies by protective height

Housing Cross Section

Slim profile (standard): 15 mm x 20 mm (0.59 x 0.79 in.)
Reinforced profile (special): 30 mm x 40 mm (1.18 x 1.57 in.)

Optical Window

Polycarbonate

Enclosure Treatment

Polyester powder coated, silicon free

Connection Type

Transmitter/receiver: 8-pin M12 micro QD

Cable Length

1, 2, 3, 5, and 8 m (3.3, 6.6, 9.8, 16.4, and 26.2 ft) cable M12 to RJ45 for MSR41 or MSR42.
Max. total system length can not exceed 10 m (32.8 ft).

Patchcords

1, 3, and 5 m (3.3, 9.8, and 16.4 ft) M12 to M12 patchcords.
Total system length cannot exceed 10 m (32.8 ft) including protective height of Micro 400, integrated cables and patchcords from M12
connector to MSR41 or MSR42.