Rockwell Automation 800T_TC Shallow, Mini and Sealed Contact Switch Blocks User Manual

Page 2

Advertising
background image

2943-99

12

1979-00

13

1000483

14

2

2

40060-226

REVISION

AUTHORIZATION

DIMENSIONS APPLY BEFORE

SURFACE TREATMENT

H

A

B

C

D

E

F

G

(DIMENSIONS IN INCHES)

TOLERANCES UNLESS

OTHERWISE SPECIFIED

REFERENCE

SHEET

OF

DWG.

B

DR.

CHKD.

APPD.

DAT E

DAT E

DAT E

ANGLES:

.XXX:

.XX:

LOCATION : MILWAUKEE, WISCONSIN

U.S.A.

SIZE

1

2

3

4

5

6

7

8

E-DOC

FORM NO. 979 (10/94)

BULLETIN 800T

SHALLOW, MINI AND SEALED

CONTACT SWITCH BLOCKS

CONTENTS FOR INSTRUCTION SHEET

PART

NO.

CHG.

CHAR.

MATERIAL

FLAT

FOLDED

FINISHED SIZE

-01

14

TWO SIDED PRINTED BODY STOCK WHITE

BODY INK BLACK.

8 " X 8"

2 " X 2"

40060-226-01(14)

Printed in U.S.A.

Standard Block: Series B and later can be mounted 2 per level up to 2 levels and can be mixed with

other block types. Series A can be mounted 1 level only and cannot be mixed with other block types.

See Note 5 for restrictions on use of 800T/TC-XD3 block.
Self Monitoring Block: Units are only functional on level 1. Units can only be used with 2
position devices. Travels of the self monitoring contacts are not suitable for 3 & 4 position
selector switches, 3 position push-pull units and toggle units.

Mini Block: This block is intended for use with either the standard contact block or the sealed switch

logic reed contact block, but should be used on level 2 only. Uses special short mounting screw.
Sealed Switch — Hi Current: Can be used only on level 1. Can be mounted alongside a stack of

2 other types of blocks. Should not be used on the following operators: 800T-K selector pushbuttons

and 800T-T 2, 3, & 4 way switch series P and earlier.
Sealed Switch — Medium Current: Can be mounted 2 per level up to 2 levels. Can be mixed with

other types of contact blocks. Uses special mounting screw with extended head.
Sealed Switch — Logic Reed: Can be mounted 2 per level up to 2 levels. Can be mixed with other

block types.

Note:
1) The contacts in the sealed switch contact blocks are hermetically sealed in a glass envelope. Dust,

dirt, oxidation, oil laden air, or other air borne contaminants do not affect the continuity of the

contacts.

2) The contacts in the standard and mini contact blocks and the operating mechanism of all the

blocks are not sealed, and should not be exposed to harsh environments.

3) The sealed switch contact blocks are suitable for use in certain hazardous environments. When

mixing standard or mini contact blocks with sealed switch contact blocks in these environments,

care should be taken to insure that all safety requirements are met.

4) Never blow dirt off of electrical components. This may force the dirt into internal mechanisms

– use vacuum.

5) Cat. No 800T/TC-XD3 contact blocks should not be used

with the following Selector Switch

Operators.

Cat No. 800T-J_KE7

Cat No.

Cat No.

800T-J_KR1

800T-J_KR7

800T-J_KT1

800T-J_KT7

800T-J_KU7

800T-N_KK4

800T-N_KM4

800H-JR_KE7

800H-JR_KR1

800T-JR_KR7

800H-JR_KT1

800H-JR_KT7

800H-JR_KU7

800H-JR_KK4

ATTENTION: Extender is for level 2 installations. Contact blocks used on operators
with posts at 2 or 4 corners of adapter plate must be mounted without spacer. Sealed
switch contact blocks should be handled with care. Do not drop.

MaxDuty: Intended for high-current or horsepower-rated applications. Recommended for use
with maintained push button operators. Can be mounted 2 per level up to 2 levels and can be
mixed with other block types.

THIS DRAWING IS THE PROPERTY OF

ROCKWELL INTERNATIONAL CORPORATION

OR ITS SUBSIDIARIES AND MAY NOT BE COPIED,

USED OR DISCLOSED FOR ANY PURPOSE

EXCEPT AS AUTHORIZED IN WRITING BY

ROCKWELL INTERNATIONAL CORPORATION

±

N/A

±

N/A

±

N/A

G. Ushakow

7/24/02

M. Jutz

7/24/02

R. Malecki

7/24/02

Advertising