Rockwell Automation 844D Optical Incremental Encoder User Manual

Rockwell Automation Equipment

Advertising
background image

Installation Instructions

Bulletin 844D Blind & ThroughĆShaft Optical Incremental Encoders

IMPORTANT: SAVE THESE INSTRUCTIONS FOR FUTURE USE.

Specifications

Electrical

Code Format 2 channels with zero index

Power Requirements 120mA (no load)

Max Output Frequency 200kHz PushĆPull (120-8192 PPR)

300kHz all other drivers (120-8192 PPR)

600kHz (above 8192 PPR)

Resolution Up to 16,384 pulses per revolution

Output Driver Capability 3487 Line driver = "40 mA

4469 Line driver = "200 mA

7272 Line driver = "40 mA

PushĆPull Single Ended Driver = "70 mA

Mechanical

Angular Acceleration 100,000 radians/sec

2

Starting Torque

@ 25_C (77_F)

9.3Ncm (13inĆoz)

Running Torque

@ 25_C (77_F)

5Ncm (7 inĆoz)

Moment of Inertia 490gcm

2

(6.9 x x 10

-3

oz-in-sec

2

)

Slew Speed 3000 rpm maximum

Shaft Loading

(120-2500 PPR)

Axial 67N (15lbs)

Radial 133N (30lbs)

Shaft Loading

(4096-16,384 PPR)

Axial 44N (10lbs)

Radial 67N (15lbs)

Permissible Shaft

Radial Movement

Static +/- 0.5mm (0.02in)

Dynamic +/- 0.1mm (0.004in)

Permissible Shaft

Axial Movement

Static +/- 0.5mm (0.02in)

Dynamic +/- 0.5mm (0.02in)

Bore Size Supports 1/2 to 1-1/8" & 30mm shafts

Environmental

Protection NEMA Type 4, 13, IP66 (IEC 529) except

terminal block connection type rated

IP40 (IEC 529) only

Housing Material Aluminum

Temperature -20_C to 85_C (-4_F to +185_F)ĊOperating

-30_C to 85_C (-22_F to +185_F)ĊStorage

Humidity 90% noncondensing

Shock 50g for 11ms

Vibration 20g from 5 to 2000Hz

Approximate Weight 0.91kg (2lbs)

Selection

844D —

A

5

A

C

1

CR

a

b

c

d

e

f

a

b

Shaft Design

Shaft Size

Ê

Code

Description

Code

Description

A

BlindĆShaft

4

1/2in

B

ThroughĆShaft

5

5/8in

6

3/4in

c

7

7/8in

Mounting Configuration

8

1.0in

Code

Description

9

1 1/8in

Tether 1/2I bolt on a

M

30mm

A

Tether, 1/2I bolt on a

7.25I dia. B.C. (to fit 8

A

7.25 dia. B.C. (to fit 8

1/2I NEMA C face)

d

Tether 3/8I bolt on a

Connection Type

B

Tether, 3/8I bolt on a

5.88I dia. B.C. (to fit 4

1/2I NEMA C f

)

Code

Description

(

1/2I NEMA C face)

C

10Ćpin Connector

C

Tether, 3/8I bolt on a

T

Terminal Block Ë

C

Tether, 3/8 bolt on a

2.5-4.0I dia. radius

1

1m (3.28ft) cable

D

AntiĆrotation pin

e

f

Power Supply and Output Ì

Resolution

Code

Description

Code Description (PPR)

1

5V DC in, 5V DC

DB

120

1

5V DC in, 5V DC

DLD out (3487)

CK

360

2

5-26V DC in, 5-26V

FW

1024

2

5-26V DC in, 5-26V

DC DLD out (7272) Í

CS

2048

3

5-15V DC in, 5-15V

CR

2500

3

5-15V DC in, 5-15V

DC DLD out (4469)

DS

4096

4

8-26V DC in,

DR

5000

4

8-26V DC in,

5V DC DLD out (3487)

FS

8192

5

10-30V DC in, 10-30V

CV

10000 Î

5

10-30V DC in, 10-30V

DC PushĆPull out

LS

16384 О

К Shaft sizes below 1.0in include an insulating insert.

Ë Terminal block unit is not rated for fluid ingress protection (IP40 (IEC 529)

only).

Ì DLD = Differential Line Driver

Í 7272 line driver has a voltage drop of 1.9V.

Î Available with power supply and output options 1, 2, 3 and 4.

Advertising