Bulletin 194rc installation (cont'd) – Rockwell Automation 194RC-Nxxxx NFPA 79 Compliant Cable Operated Disconnect User Manual

Page 2

Advertising
background image

Figure 1-2 Securing Toggle Mechanism and Handle to Flange

2. Install handle to enclosure by placing the outer handle mechanism with the attached gasket over the enclosure cutout. Insert
the top mounting screw with lockwasher through the enclosure and thread it into the outer handle mechanism for a few turns but
not all the way. (See Figure 1-2).
3.
Slide the toggle mechanism assembly over the top handle mounting screw. Insert the bottom handle mounting screw and
lockwasher through the toggle mechanism assembly, through the enclosure and into the handle. Tighten both mounting screws
to specified torque. (See Figure 1-2).
4.
Assemble adapter link to actuator link. Tighten to specified torque. (See Figure 1-3).
5. Align adapter link with the bell crank. Attach bell crank to adapter link with shoulder bolt and nut. Tighten to specified torque.
(See Figure 1-4).
6. Mount door hasp to handle using the two screws provided with the handle. (See Figure 1-2).

7. Operate handle mechanism to ensure functionality. To operate either close door or defeat door interlock.
8. If minor adjustments are necessary, refer to adjustment checklist (Page 3).
9. Install appropriate door hardware (supplied). (See Figure 1-7).

Bulletin 194RC Installation (Cont'd)

Bail

23 - 37 lb-in

Max.

6" Min.

Bend Radius

Connect Adapter Link

to Bell Crank with

Shoulder Bolt and Nut

These items are to be assembled

after handle is mounted to enclosure

Toggle
Mechanism

Rotate Bell Crank

and Adaptor Link

to line up holes

(2)

Adapter Link

Door
Hasp

Handle
Mechanism

Actuator Link

Actuator Link

Shoulder Bolt

18 - 20 lb-in

18 - 20 lb-in

7 - 11 lb-in

Max.

Figure 1-3 Assembly of Adapter Link to Actuator Link

Actuator Link Screw

Figure 1-4 Assembly of Adapter Link to Bell Crank Using Shoulder Bolt

After aligning assemble with

Shoulder Bolt and Nut

Tighten to 18 - 20 lb-in.

Assemble Adaptor Link

with Screw to Actuator Link

Tighten to 18 - 20 lb-in.

Note: Make sure handle is in OFF position.

Note: Make sure handle is in OFF position.

(2)